The hottest side is troubleshooting ntrip common s

2022-09-23
  • Detail

Founder typesetting ntrip common software faults and solutions

founder typesetting ntrip has many users, especially in newspapers and output centers. The publishing time of these units is very tight. After the system breaks down, there is little time left for maintenance personnel. If users do not pay attention to summary and accumulation, it will often affect publishing. If users can master some methods to deal with faults in practice, the publishing process can become relatively easy

founder's troubleshooting ntrip fault includes two aspects: one is caused by the software itself, which is called soft fault; The other is caused by hardware faults such as interface card, dongle, card and signal line, which is called hard fault

because hardware replacement requires a certain period, and the general user cannot have a backup card similar to the mechanical universal experimental function, the hardware fault resolution cycle is relatively long, and it is difficult for the user to solve it by himself

however, soft faults are generally caused by the operating system, ntrip software and other reasons. Combined with the characteristics of founder ntrip software, users can solve the faults by themselves under the guidance of Founder engineers. The efficiency of solving problems in this way is very high and the effect is very good. This paper introduces some soft faults and solutions summarized in practical work for peer reference

ntrip system platform main parameters: NT server 4 Chinese Version (patch 6), founder PSP ntrip version 1.51

soft fault 1: Fang Zheng typesetting ntrip, running ntrip program is normal, but when opening PS sending file, the system prompts: "the system is missing 1 character" and automatically terminates rip

solution: routine inspection shows that illegal characters are used in the front-end Feiteng group version. However, this inspection found that the front-end Feiteng typesetting was normal, and the detail layout was normal. The missing character reported by the system is estimated to be related to the font, but in ntrip, there are only two ways to work on the font, either reload the font and slowly open the oil delivery valve, or use the "font reset" function in ntrip software. Because in ntrip version 1.51, the font must be reinstalled together with the software, so first try the "font reset" function to see if it can be solved. As a result, the problem was solved after the font was reset

soft fault 2: the ntrip program runs normally, but the content in the "information window" cannot be cleared

solution: generally, after ntrip software runs, there is the option of "clear information" in the menu, and the system can automatically clear the contents in the window. However, it doesn't work at this time. It was judged that it was the problem of the software itself, so after backing up all the folders generated by ntrip in the system, reinstall founder ntrip software and clear the "information window" normally. Comparing folders, many files were found in the sysdata directory under the pspnt directory when the fault was found. Delete the newly installed ntrip software, restore the original backup ntrip software, and run it. The fault remains. Delete all files in the pspnt sysdata directory, and then run ntrip. It is normal

soft fault 3: the ntrip program runs normally, but after the program is started, the rip system automatically sends PS files that have been sent the previous day

solution: first, judge whether the virus is causing trouble, but after inspection, it is found that there is no virus in the system. Ntrip program sends PS files normally, that is, after each startup, it automatically sends PS files that have been sent the previous day. It may be the problem of ntrip software itself. Then delete all files in pspnt \ sysdata directory, and then run ntrip. It is normal

soft fault 4: after Fangzheng arranges ntrip, the main program window appears, but after a blank information window and a blank operation menu appear, the program dies and cannot be operated

solution: first, confirm whether there is a problem with the computer hardware, but after inspection, it is found that the NT server software system starts and runs normally, and the computer board should be free of problems. Is there a problem with the dongle? However, the system did not report the error of "invalid dongle", and the focus was again on ntrip software. Then delete all files in pspnt \ sysdata directory, and then run ntrip. It is normal

soft fault 5: when ntrip runs, the system prompts: "run timr error!", The program terminates automatically

solution: the first possibility is that the dongle is broken. But because there is no spare dog on hand, I can't try it. Running other programs in the computer, such as ACDSee, word, etc., are normal. So all ntrip software in the system was deleted, then reinstalled, and then ran. The fault remained the same. Ask the operator carefully again, have you installed or deleted software in the computer recently? I learned that a new version of anti-virus software had just been installed the day before, and then checked and found that the newly installed anti-virus software was running the "file real-time monitoring" function in the background. It is suspected that it is caused by the conflict between programs, so turn off the "file real-time monitoring" function of the anti-virus software, and then run ntrip. It is normal

soft fault 6: Founder Imagesetter ntrip runs normally, but after the imagesetter is finished, press the "slice" option, and the imagesetter does not respond

solution: since the software cannot control the slicing, carry out the hardware control slicing operation on the operation panel of the Imagesetter, which is normal. Then restart ntrip software, press the "slice" option after sending the slice, and the software controls the slice to work normally with the development of electronic technology and computer technology

source: printing technology

this article is from the Internet, and the copyright belongs to the original author. It is only for everyone to share and check whether the calibration value, calibration value or other information in hardware parameters have been manually changed. If the author believes that infringement is involved, please contact us, and we will delete it immediately after verification

Copyright © 2011 JIN SHI